Mount Surface
Voltage 24VDC
Voltage
48VDC
Voltage
110VDC
Voltage
110VAC
Voltage
240VAC
Operating Current XEN1 - 0.93 Amps @24VDC
Operating Current
XEN1 - 0.81 Amps @48VDC
Operating Current
XEN1 - 0.61 Amps @110VDC
Operating Current
XEN1 - 0.48 Amps @110VAC
Operating Current
XEN1 - 0.38 Amps @240VAC
Operating Current
XEN4 - 1.90 Amps @24VDC
Operating Current
XEN4 - 1.22 Amps @48VDC
Operating Current
XEN4 - 0.92 Amps @110VDC
Operating Current
XEN4 - 0.53 Amps @110VAC
Operating Current
XEN4 - 0.41 Amps @240VAC
Light Source/Lamp Style Xenon Lens
Flash Rate/Minute 80 (Model XEN1 Only)
Exterior Dome Toughened Glass
Dome Guard 316 Stainless Steel
Colors Amber
Colors
Blue
Colors
Clear
Colors
Green
Colors
Red
Colors
Yellow
Operating Temperature Minimum, Ex d and Ex de -40.00 °F
Operating Temperature Maximum, Ex d and Ex de 131.00 °F
Ingress Protection (IP) IP66
Certification Marking Ex d IIB T4 Ex tD A21
Certification Marking
Ex de IIB T4 Ex tD A21
Terminals Ex d - 4 Way Block Mounted PCB
Terminals
Ex de - 12 Way Block In Terminal Chamber
Cable Entries Ex d and Ex de - 4 entries, M20 x 1.5
Body Marine Grade Alloy Painted Regal Red
Height 9.840 in
Width 10.040 in
Length 8.230 in
Mount Surface
Voltage 24VDC
Voltage
48VDC
Voltage
110VDC
Voltage
110VAC
Voltage
240VAC
Operating Current XEN1 - 0.93 Amps @24VDC
Operating Current
XEN1 - 0.81 Amps @48VDC
Operating Current
XEN1 - 0.61 Amps @110VDC
Operating Current
XEN1 - 0.48 Amps @110VAC
Operating Current
XEN1 - 0.38 Amps @240VAC
Operating Current
XEN4 - 1.90 Amps @24VDC
Operating Current
XEN4 - 1.22 Amps @48VDC
Operating Current
XEN4 - 0.92 Amps @110VDC
Operating Current
XEN4 - 0.53 Amps @110VAC
Operating Current
XEN4 - 0.41 Amps @240VAC
Light Source/Lamp Style Xenon Lens
Flash Rate/Minute 80 (Model XEN1 Only)
Exterior Dome Toughened Glass
Dome Guard 316 Stainless Steel
Colors Amber
Colors
Blue
Colors
Clear
Colors
Green
Colors
Red
Colors
Yellow
Operating Temperature Minimum, Ex d and Ex de
Operating Temperature Maximum, Ex d and Ex de
Ingress Protection (IP) IP66
Certification Marking Ex d IIB T4 Ex tD A21
Certification Marking
Ex de IIB T4 Ex tD A21
Terminals Ex d - 4 Way Block Mounted PCB
Terminals
Ex de - 12 Way Block In Terminal Chamber
Cable Entries Ex d and Ex de - 4 entries, M20 x 1.5
Body Marine Grade Alloy Painted Regal Red
Height
Width
Length